Challenge
The client reported high vibrations at the non-drive end of the electric motor drive for the bow thruster on one of their container vessels. The vessel operated on a schedule requiring regular short port calls, and loss of the bow thruster meant an additional tug was required during berthing, increasing operating costs.
An urgent investigation was required to assess vibration levels and define a scope to reduce them to acceptable limits. The urgency was compounded by a forthcoming dry docking where any modifications would need to be implemented.
The original equipment manufacturer (OEM) of the bow thruster was no longer in operation.
Solution
Lloyd’s Register (LR) Advisory Technical & Failure Investigation (TFI) Department proposed a technical investigation combining onboard inspection, measurements and desktop finite element structural analysis of the bow thruster and surrounding hull structure. This would support a redesign study of the motor pedestal and top bracing to address the vibration.
Approach taken
A TFI specialist attended the vessel at anchorage to inspect the bow thruster in operation, take vibration measurements on the motor and modal measurements of surrounding structure.
Vibration levels exceeded the specified limits by a factor of four. To comply with permissible limits, a 78% attenuation level was required for the bow thruster operating at 100% power and full pitch. The excitation source was identified as the propeller blade passing frequency, which aligned with the natural frequency of the tunnel and hull support structure, causing resonance and high vibration at the non-drive end of the motor.
Using OEM and ship hull structure drawings, the bow thruster and surrounding support structure were modelled in ANSYS finite element software to capture the mass and stiffness distribution within the thruster column.
The objectives were to match measured onboard natural frequencies and mode shapes to establish the baseline response and evaluate achievable attenuation using a stiffening arrangement involving minimal welding and structural modification while meeting the 78% attenuation requirement.
Key activities and outpouts
- Onboard investigation and measurement of bow thruster vibration levels in operation and modal frequency of the hull structure around the thruster
- Preparation and calibration of a finite element model to match onboard measurements as the baseline response
- Assessment of minor structural modification around the tunnel to predict vibration response in longitudinal (ux) and transverse (uy) directions at the non-drive end of the motor
- With the selected modified structure arrangement, ux and uy responses were reduced by 96.2% and 82.1% respectively, relative to the baseline, satisfying the required target attenuation of 78%
- Delivery of a detailed technical report including the proposed modified structure arrangement with dimensional details.
Key customer benefits
- Understanding of bow thruster motor condition, allowing intervention before failure
- Structural modification details provided in time for dry docking
- Avoided higher-cost failure repairs and additional tug requirements
- Lower risk of operational disruption
- Learning applicable to sister ships in the fleet.
Project outcome
LR Advisory’s TFI team’s analysis confirmed the excitation mechanism identified during onboard assessment as the bow thruster blade passing frequency. The finite element model predicted natural frequency of the baseline thruster to closely match the onboard measurements.
A thruster tunnel pedestal stiffening optimisation study assessed attenuation margins for transverse and longitudinal response at the motor non-drive end bearing. Baseline modal frequencies were predicted with good accuracy, with the relative difference between measured and predicted values better than 1.5%.
With the proposed tunnel pedestal stiffening arrangement, natural frequencies could be increased by at least 52% and 21% in the longitudinal and transverse
directions respectively relative to the baseline values.
Forced damped analysis confirmed that this increase in natural frequencies enabled attenuation of vibratory displacement at the motor non-drive end bearing to meet the 78% target.
Impact on customer's business & operations
By identifying the cause of the vibration, the client was able to implement a relatively simple structural modification to shift the natural frequency of the tunnel motor pedestal away from the bow thruster propeller blade passing frequency, preventing resonance and high vibration at the non-drive end of the motor.
This strengthened bow thruster reliability and reduced the risk of unplanned costly interruptions to operations.
Conclusion
The investigation provided a clear technical basis to identify the cause of the vibration and implement corrective action. A targeted structural modification was defined in time to prevent motor failure and improve machine reliability.